Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.231
Filtrar
1.
BMC Ophthalmol ; 24(1): 174, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627647

RESUMO

PURPOSE: To evaluate the long-term clinical outcomes of femtosecond thin-flap LASIK (femto-LASIK) for correction of refractive error after penetrating keratoplasty in keratoconus-affected eyes. SETTING: a private ophthalmology clinic. DESIGN: Prospective interventional case series. METHODS: This prospective interventional case series enrolled 22 eyes of 22 patients who underwent femto-LASIK for the management of post-penetrating keratoplasty ametropia. The refractive error, uncorrected (UDVA), and corrected (CDVA) distance visual acuities and vector analysis were reported in short-term and long-term period after surgery. RESULTS: The mean age was 32.7 ± 7.5 years (range, 23 to 47 years) at the surgery time. The average time between PK and femto-LASIK was 42.5 ± 31.7 months. The average follow-up duration after femto-LASIK was 81.2 ± 18.6 months. The mean preoperative UDVA significantly improved from 0.47 ± 0.15 logMAR to 0.35 ± 0.14 logMAR at 12 months (P = 0.048) and 0.4 ± 0.17 at final follow-up exam (P = 0.007). CDVA was 0.22 ± 0.1 at baseline which improved to 0.18 ± 0.15 and 0.15 ± 0.1 logMAR at 12 and 81 months, respectively. (Ps = 0.027, 0.014). The mean cylinder before surgery was - 5.04 ± 1.4D which significantly decreased to -1.5 ± 0.8 D at 12 months postoperatively. (P < 0.001). There was a significant increase in refractive astigmatism from 12 months to 81 months postoperatively (-3.1 ± 2.0, P = 0.002). At the final visit, the efficacy index was 0.83, and the safety index was 1.16. CONCLUSIONS: Despite the short-term outcome indicated that femo-LASIK was effective for correction of post-keratoplasty ametropia during short-term period, a notable regression in its effect was observed in the long-term follow-up. Therefore, the predictability of this technique might decrease in the long-term.


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Erros de Refração , Humanos , Adulto , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Ceratoplastia Penetrante/efeitos adversos , Estudos Prospectivos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Refração Ocular , Lasers , Resultado do Tratamento , Lasers de Excimer/uso terapêutico
2.
BMC Ophthalmol ; 24(1): 110, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454381

RESUMO

BACKGROUND: To investigate the change in the distance between corneal apex and pupil center after small-incision lenticule extraction (SMILE) or implantable collamer lens (ICL) implantation and its correlation with surgical-induced astigmatism (SIA). METHODS: This study included patients who had undergone SMILE (n = 112) or ICL implantation (n = 110) to correct myopia and myopic astigmatism. The angle kappa was measured using a Scheimpflug imaging device (Pentacam) and represented as Cartesian values between the pupil center and the corneal vertex (X, Y) and chord u ([Formula: see text]orientation), and was compared pre- and post-operative. RESULTS: Following SMILE, the magnitude of chord u[Formula: see text]) significantly increased in both eyes (Wilcoxon signed-rank test, OD: P<0.001; OS: P=0.007), while no significant change was observed in the orientation. A significant correlation was found between the J0 component of SIA and the change in the magnitude of chord u for both eyes (OD: R2=0.128, P<0.001; OS: R2=0.033, P=0.004). After ICL implantation, the orientation of the chord u was significantly different in the right eye (Wilcoxon signed-rank test, P = 0.008), and the Y-intercept significantly decreased in both eyes (Wilcoxon signed-rank test, P<0.001). A significant correlation was found between J0 of SIA and the change in the magnitude of chord u for the right eyes (R2=0.066, P=0.002). A significant correlation was found between J45 of SIA and the change in the magnitude of chord u for the left eyes (R2=0.037, P=0.044). CONCLUSIONS: The magnitude of the chord u increased following the SMILE procedure, whereas the Y-intercept significantly decreased after ICL implantation. SIA was related to the change in the magnitude of chord u.


Assuntos
Astigmatismo , Humanos , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Astigmatismo/cirurgia , Refração Ocular , Acuidade Visual , Pupila , Topografia da Córnea
3.
Medicine (Baltimore) ; 103(9): e37340, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38428861

RESUMO

To compare changes in the spherical component, regular astigmatism, and irregular astigmatism of the anterior surface of the cornea after small-incision lenticule extraction (SMILE) and transepithelial photorefractive keratectomy (TransPRK). Fifty-six patients underwent SMILE in 56 eyes, and 68 patients underwet TransPRK in 68 eyes. The right eye was chosen to enter the group. Six months after the procedure, Scheimpflug images were acquired, and Fourier analysis of the anterior surface of patients' corneas was performed using the Pentacam built-in software. Fourier parameters encompass various measurements such as the steepest radius of the curvature and average eccentricity of the spherical components (SphRmin and SphEcc), maximum decentration (MaxDec), central and peripheral regular astigmatism (regular astigmatism at the center [AstC] and regular astigmatism at the periphery [AstP]), and irregularity (Irr). At 6 months postoperatively, SphEcc decreased significantly (P < .001), MaxDec increased significantly (P < .001), and Irr increased insignificantly (P = .254) in the SMILE group. SphEcc decreased significantly (P < .001) and MaxDec and Irr increased significantly (P < .001) in the TransPRK group. TransPRK caused greater changes in SphEcc, MaxDec, and Irr on the anterior corneal surface than SMILE (P < .05). The amount of MaxDec-induced changes in SMILE and TransPRK was significantly correlated with the amount of higher-order aberrations and spherical aberration changes (P < .05). SMILE and TransPRK increase overall irregular astigmatism on the anterior surface of the cornea, more so with TransPRK, where changes in decentration are associated with with increased higher-order aberrations.


Assuntos
Astigmatismo , Doenças da Córnea , Miopia , Ceratectomia Fotorrefrativa , Humanos , Ceratectomia Fotorrefrativa/efeitos adversos , Ceratectomia Fotorrefrativa/métodos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Análise de Fourier , Acuidade Visual , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Córnea/cirurgia , Doenças da Córnea/cirurgia
4.
Med Eng Phys ; 123: 104076, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38365329

RESUMO

The birefringent nature of the human cornea plays an important role in comprehending its structural behavior in both diseased and surgical conditions. During corneal transplantation, irregular astigmatism is a common post-surgical complication that depends on the characteristics of suturing. Four human cadaver corneas are subjected to an in-vitro model of a typical full-thickness penetrating keratoplasty (PK) procedure using 16 simple interrupted 10-0 vicyrl sutures. The birefringence of these four corneas is analyzed using digital photoelasticity and compared with the control cornea (without PK). It is found that the sutures and their mutual interaction influence the morphology of the peripheral birefringence of the cornea. The findings of the present investigation are pertinent to intraoperative suture management during PK. Results suggest conserving the typical diamond-shaped morphology of peripheral birefringence would ensure uniform distribution of sutures. Therefore, birefringence imaging could be useful in suture management to ensure proper apposition of the graft-host junction, thus minimizing the risk of irregular astigmatism.


Assuntos
Astigmatismo , Ceratoplastia Penetrante , Humanos , Ceratoplastia Penetrante/efeitos adversos , Ceratoplastia Penetrante/métodos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Topografia da Córnea/efeitos adversos , Acuidade Visual , Técnicas de Sutura/efeitos adversos , Córnea/cirurgia , Complicações Pós-Operatórias , Colágeno
5.
J Refract Surg ; 40(2): e73-e78, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38346124

RESUMO

PURPOSE: To identify risk factors that increase the likelihood of re-treatment following refractive surgery in patients with mixed astigmatism. METHODS: This was a retrospective study including patients who underwent either laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) between 2000 and 2019 and had mixed astigmatism (spherical error of +0.50 D or greater and spherical equivalent of less than 0.00 diopters [D]). Patients were divided into two groups according to whether they underwent re-treatments during the study period. RESULTS: Overall, 785 eyes (785 patients) were included. In total, 5.2% of the eyes (n = 41) underwent re-treatment. The re-treatment group was more likely to have preoperative high astigmatism (80.5% vs 48.3%, P < .001), moderate to high hyperopia (36.6% vs 22.3%, P = .035), and to have undergone surgery earlier during the study period (P < .001). They were also more likely to have undergone surgery using the Wave-Light EX200 rather than the EX500 laser platform (Alcon Laboratories, Inc) (P < .001), have a treated optical zone of 6 mm rather than 6.5 mm (P < .001 for both), and their maximum ablation depth was greater (P < .001). There was no difference between the re-treatment and control groups regarding procedure type (PRK vs LASIK). Binary logistic regression found preoperative high astigmatism (odds ratio = 3.97, P < .001) and the type of laser platform used (EX200, odds ratio = 7.78, P < .001) as the only independent factors associated with re-treatment. CONCLUSIONS: Re-treatment rates following correction of mixed astigmatism were 5.2% over 20 years. Use of a sixth-generation laser platform significantly reduced the risk of re-treatment. Presence of high astigmatism is a significant risk factor for re-treatment. There was no difference in retreatment risk between PRK and LASIK. [J Refract Surg. 2024;40(2):e73-e78.].


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ceratectomia Fotorrefrativa , Humanos , Córnea/cirurgia , Astigmatismo/cirurgia , Astigmatismo/etiologia , Acuidade Visual , Estudos Retrospectivos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Miopia/etiologia , Ceratectomia Fotorrefrativa/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Resultado do Tratamento
6.
Int Ophthalmol ; 44(1): 2, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38315421

RESUMO

PURPOSE: To investigate the acute effects of upper eyelid blepharoplasty on intraocular pressure (IOP) and ocular biometric parameters. METHOD: This prospective cross sectional study examined the eyes of 49 patients with dermatochalasis. Following a detailed ophthalmological examination, corneal topography was used to evaluate the eyes mesopic and photopic pupil diameter, anterior chamber depth, and corneal astigmatism on the day of surgery and on days first and seventh postoperatively. Ocular biometry was used to assess axial length and intraocular lens power. Goldmann applanation tonometry was used to measure intraocular pressure. RESULTS: Forty-nine eyes (26 males and 23 females) of 49 patients aged between 44 and 76 years (mean 61 ± 7.9) were included in our study. The mean anterior chamber depth (ACD) was 2.90 ± 0.37 mm preoperatively, 3.00 ± 0.29 mm at postoperative day first, and 3.04 ± 0.29 mm at postoperative day seventh, and the increase in anterior chamber depth was statistically significant (p < 0.001). The mean astigmatism values were measured as preoperative 0.73 ± 0.69 D, postoperative first day 0.93 ± 0.81 D, and postoperative seventh day 1.26 ± 0.90 D. The increase in astigmatism values was statistically significant (p < 0.001). The mean pupil diameter measurements in the mesopic environment were 4.20 ± 0.61 mm preoperatively, 4.40 ± 0.59 mm on the first postoperative day, and 4.39 ± 0.57 mm on the seventh postoperative day, and there was a statistically significant difference between the three measurements (p = 0.03). The mean IOP measurements of the patients were 15.91 ± 3.51 mmHg preoperatively, 16.81 ± 3.36 mmHg on the first postoperative day, and 16.97 ± 3.13 mmHg on the seventh postoperative day. The increase between these three measurements was statistically significant (p = 0.013). CONCLUSION: This study includes important insights into the potential acute phase impact of blepharoplasty surgery on ocular findings. Patients undergoing upper eyelid surgery should be informed about the possible change in ocular biometric parameters, intraocular pressure, and pupil diameter.


Assuntos
Astigmatismo , Blefaroplastia , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Pressão Intraocular , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Estudos Prospectivos , Estudos Transversais , Implante de Lente Intraocular , Pálpebras/cirurgia , Biometria
7.
Sci Rep ; 14(1): 1868, 2024 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-38253641

RESUMO

The influence of environmental factors like smoking and alcohol on myopia and astigmatism is controversial. However, due to ethical concerns, alternative study designs are urgently needed to assess causal inference, as mandatory exposure to cigarettes and alcohol is unethical. Following comprehensive screenings, 326 single nucleotide polymorphisms (SNPs) related to myopia and astigmatism were included in the dataset. To validate the causal association between exposures such as cigarette smoking, alcohol consumption, and coffee intake, and outcomes namely astigmatism and myopia, five regression models were employed. These models encompassed MR-Egger regression, random-effects inverse-variance weighted (IVW), weighted median estimator (WME), weighted model, and simple model. The instrumental variables utilized in these analyses were the aforementioned SNPs. Apply Cochran's Q test to determine heterogeneity of SNPs; if heterogeneity exists, focus on IVW model results. The IVW model showed a 1.379-fold increase in the risk of astigmatism (OR = 1.379, 95%CI 0.822~2.313, P = 0.224) and a 0.963-fold increase in the risk of myopia (OR = 0.963, 95%CI 0.666~1.393, P = 0.841) for each unit increase in smoking. For each unit increase in coffee intake, the risk of astigmatism increased 1.610-fold (OR = 1.610, 95%CI 0.444~5.835, P = 0.469) and the risk of myopia increased 0.788-fold (OR = 0.788, 95%CI 0.340~1.824, P = 0.578). For each additional unit of alcohol consumption, the risk of astigmatism increased by 0.763-fold (OR = 0.763, 95%CI 0.380~1.530, P = 0.446), and none of the differences were statistically significant. However, for each unit of alcohol consumption, the risk of myopia increased by 1.597 times, and the difference was statistically significant (OR = 1.597, 95%CI 1.023~2.493, P = 0.039). The findings indicate that alcohol consumption is a risk factor for myopia but smoking and coffee intake do not affect its development. Additionally, there is no association between smoking, alcohol consumption, coffee intake, and the risk of astigmatism.


Assuntos
Astigmatismo , Fumar Cigarros , Miopia , Humanos , Astigmatismo/etiologia , Astigmatismo/genética , Café/efeitos adversos , Análise da Randomização Mendeliana , Consumo de Bebidas Alcoólicas/efeitos adversos , Miopia/etiologia , Miopia/genética , Etanol
8.
BMC Ophthalmol ; 24(1): 45, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38287289

RESUMO

BACKGROUND: To evaluate the possible topographic and surgical risk factors for high postoperative residual astigmatism in patients who undergo small-incision lenticule extraction (SMILE) surgery and have different myopia degrees. METHODS: A retrospective cohort study was conducted, and patients who underwent SMILE surgery were enrolled. A total of 80 and 150 eyes from 40 to 75 individuals, respectively, were selected as the low myopia and high myopia groups. The demographic data, visual acuity, refraction, topographic parameters and surgical settings were recorded. Multiple linear regression with interaction tests were performed to survey the risk factors for high postoperative residual astigmatism in each group. RESULTS: Five (6.25%) and 9 (6.00%) eyes presented with high postoperative residual astigmatism in the low myopia and high myopia groups, respectively, but these differences were not significant (P = 0.569). A steep corneal curvature was correlated with a greater risk of high postoperative residual astigmatism in the low myopia group (P = 0.015), while a higher degree of cycloplegic cylinder power, steeper corneal curvature, greater topographic cylinder power, smaller optic zone and longer incision length were associated with a high rate of postoperative residual astigmatism in the high myopia group (all P < 0.05). In addition, the interaction effects of cycloplegic and topographic cylinder power and longer incision length on the incidence of high postoperative residual astigmatism development were more evident in the high myopia group than in the low myopia group (all P < 0.05). CONCLUSIONS: A steep corneal curvature correlates with a high risk of high postoperative residual astigmatism after SMILE surgery, and a higher degree of cycloplegic and topographic cylinder and longer incision are associated with high postoperative residual astigmatism in individuals with high myopia.


Assuntos
Astigmatismo , Cirurgia da Córnea a Laser , Miopia , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Estudos Retrospectivos , Midriáticos , Topografia da Córnea , Microcirurgia , Refração Ocular , Miopia/cirurgia , Córnea/cirurgia , Substância Própria/cirurgia , Lasers de Excimer/uso terapêutico
9.
BMC Ophthalmol ; 24(1): 40, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38273262

RESUMO

BACKGROUND: This study aimed to compare the corneal high-order aberrations and surgically induced astigmatism between the clear corneal incision and limbus tunnel incision for posterior chamber implantable collamer lens (ICL/TICL) implantation. METHODS: A total of 127 eyes from 73 myopic patients underwent ICL V4c implantation, with 70 eyes receiving clear corneal incisions and 57 eyes receiving limbus tunnel incisions. The anterior and back corneal surfaces were measured and the Root Mean Square of all activated aberrations (TRMS) was calculated, including higher-order aberration (HOA RMS), spherical aberration Z40, coma coefficients (Coma RMS) Z3-1 Z31, and surgically induced astigmatism (SIA). The measurements were taken preoperatively and postoperatively at 1 day, 1 week, and 1, 3, and 6 months. In this study, the corneal higher-order aberration was estimated as the Zernike coefficient calculated up to 5th order. The measurements were taken at a maximum diameter of 6.5 mm using Pentacam. RESULTS: One week after the operation, the corneal back Z31 of the clear corneal incision group was 0.06 ± 0.06, while the limbus tunnel incision group showed a measurement of 0.05 ± 0.06 (p = 0.031). The corneal back Z40 of the clear corneal incision group was -0.02 ± 0.25, compared to -0.04 ± 0.21 in the limbus tunnel incision group (p = 0.01). One month after the operation, the corneal back SIA of the clear corneal incision group was 0.11 ± 0.11, compared to 0.08 ± 0.11of the limbus tunnel incision group (p = 0.013), the corneal total SIA of the clear corneal incision group was 0.33 ± 0.30, compared to 0.15 ± 0.16 in the limbus tunnel incision group (p = 0.004); the clear corneal incision group exhibited higher levels of back astigmatism and total SIA than the limbus tunnel incision in the post-operation one month period. During the 6- month post-operative follow-up period, no significant difference in Z31, Z40, and other HOA RMS data was observed between the two groups. The total SIA of the corneal incision group and the limbus tunnel incision group were 0.24 ± 0.14 and 0.33 ± 0.32, respectively (p = 0.393), showing no significant difference between the two groups 6 months after the operation. CONCLUSION: Our data showed no significant difference in the high-order aberration and SIA between clear corneal incision and limbus tunnel incision up to 6 months after ICL-V4c implantation.


Assuntos
Astigmatismo , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Implante de Lente Intraocular , Coma/cirurgia , Córnea/cirurgia , Pseudofacia/cirurgia
10.
Klin Monbl Augenheilkd ; 241(2): 186-191, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36796415

RESUMO

PURPOSE: To compare the effect of implanting the capsular tension ring (CTR) before or after a toric intraocular lens (IOL) on rotational stability in patients with cataract and astigmatism. METHODS: This is a randomized retrospective study. Patients who underwent phacoemulsification combined with toric IOL implantation due to cataract and astigmatism between February 2018 and October 2019 were enrolled in the study. Group 1 consisted of 53 eyes of 53 patients in whom the CTR was placed into the capsular bag after the implantation of the toric IOL. On the other hand, group 2 consisted of 55 eyes of 55 patients in whom the CTR was placed into the capsular bag before implantation of the toric IOL. The two groups were compared in terms of preoperative and postoperative astigmatism, uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), and postoperative IOL rotation degree. RESULTS: There were no significant differences between the two groups related to age and sex (p > 0.05) or the mean preoperative spherical value, UCVA, BCVA, and corneal astigmatism (p > 0.05). Although the mean postoperative residual astigmatism of the first group (- 0.29 ± 0.26) was lower than that of the second (- 0.43 ± 0.31), the difference was not statistically significant (p = 0.16). The mean degree of rotation was 0.75 ± 2.66° in group 1 and 2.90 ± 6.57° in group 2, which was found to be statistically significant (p = 0.02). CONCLUSION: The implantation of CTR after a toric IOL provides further rotational stability and more effective astigmatic correction.


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Astigmatismo/cirurgia , Estudos Retrospectivos , Catarata/complicações , Catarata/diagnóstico , Refração Ocular
11.
Jpn J Ophthalmol ; 68(1): 42-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38001368

RESUMO

PURPOSE: To investigate corneal refractive power (CR) and astigmatism (AS) in 6- to 18-year-old children with a history of retinopathy of prematurity (ROP) and birth weight of <1500 g who either did or did not undergo retinal photocoagulation (PC). STUDY DESIGN: Retrospective study. METHODS: We examined 143 eyes of 77 children in 2021. The children were divided into three groups for evaluation of CR and AS: those with a birth weight of ≥2500 g (normal birth weight [NBW] group, 13 eyes) as controls, those with spontaneously resolved ROP (sr-ROP group, 27 eyes), and those who underwent PC for treatment of ROP (PC-ROP group, 103 eyes). Swept-source anterior segment optical coherence tomography was used to analyze the cornea. RESULTS: The median CR in the NBW, sr-ROP, and PC-ROP groups was 42.2 (41.3, 42.8) diopters (D), 44.5 (43.2, 45.5) D, and 45.2 (43.8, 46.6) D, respectively. The median AS in the NBW, sr-ROP, and PC-ROP groups was 1.2 (1.0, 1.5) D, 1.1 (0.8, 1.6) D, and 2.1 (1.4, 2.7) D. In the PC-ROP group, the with-the-rule astigmatic axis was 97%. In all three groups, a strong positive correlation was found between the mean anterior and posterior CR (NBW: r=0.795, sr-ROP: r=0.842, PC-ROP: r=0.890) and AS (NBW: r=0.883, sr-ROP: r=0.841, PC-ROP: r=0.860). CONCLUSION: CR was significantly higher in the sr-ROP (p=0.013) and PC-ROP (p<0.001) groups than in the NBW group. The PC-ROP group had significantly more AS than the sr-ROP group. There was a strong correlation between the anterior and posterior CR and AS.


Assuntos
Astigmatismo , Erros de Refração , Retinopatia da Prematuridade , Recém-Nascido , Criança , Humanos , Adolescente , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Peso ao Nascer , Retinopatia da Prematuridade/complicações , Retinopatia da Prematuridade/diagnóstico , Retinopatia da Prematuridade/cirurgia , Estudos Retrospectivos , Erros de Refração/diagnóstico , Córnea/diagnóstico por imagem , Idade Gestacional
12.
Photodiagnosis Photodyn Ther ; 45: 103895, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37977225

RESUMO

PURPOSE: To compare dominant and non-dominant hand phacoemulsification surgery outcomes. METHODS: This retrospective, single-center study included 300 patients who underwent phacoemulsification surgery by a single, right-handed surgeon. The patients were divided into two groups according to whether the surgeon used his dominant or non-dominant hand during surgery. Right eye operations were performed with the right hand, and left eye operations were performed with the left hand. Detailed ophthalmological examinations were performed on all patients preoperatively and postoperatively. Intraoperative phacoemulsification parameters, the presence of intraoperative and postoperative complications, postoperative refractive errors, visual acuity, and surgically induced astigmatism values were compared between the groups. RESULTS: There were 171 patients in the dominant hand phacoemulsification group and 129 patients in the non-dominant hand phacoemulsification group. The distributions of age, gender, systemic diseases, and lens opacification were similar between the groups (p>0.05, for all). No statistically significant difference was observed between the two groups in terms of total operation time, phaco power, ellips fx, or ultrasonic time (p>0.05, for all). There was also no significant difference in relation to intraoperative and postoperative complication distributions, postoperative third-month refractive errors, visual acuity, or surgically induced astigmatism values (p>0.05, for all). CONCLUSION: This study demonstrated that cataract surgery performed by a single surgeon can be effectively and safely performed using both hands on patients in a real operating theater environment. More objective results can be obtained with surgeries performed by a larger number of experienced surgeons.


Assuntos
Astigmatismo , Fotoquimioterapia , Erros de Refração , Cirurgiões , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Estudos Retrospectivos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Complicações Pós-Operatórias/epidemiologia
14.
Rom J Ophthalmol ; 67(3): 275-282, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37876511

RESUMO

Purpose: To measure changes in posterior corneal curvature after steep axis phacoemulsification and investigate the possibility of its effect on SIA. Methods: This was a prospective longitudinal study on 60 consecutive eyes of age-related cataract with regular astigmatism and absence of co-morbidities undergoing uneventful cataract surgeries with main incision at steep meridian. Preoperative and 4 weeks postoperative measurements of anterior and posterior corneal curvatures using Scheimpflug based corneal topographer were performed. Posterior corneal curvature was assessed at 3, 5- and 7-mm diameters. Results: The study found a statistically significant change in posterior corneal K1, K2 and mean astigmatism in all zones (3, 5 and 7 mm) at 4 weeks postoperative, when compared to preoperative readings. Conclusion: Posterior keratometry is likely to be an important determinant of Surgically Induced Astigmatism (SIA) and should be factored in for refractive cataract surgery.


Assuntos
Astigmatismo , Catarata , Facoemulsificação , Humanos , Facoemulsificação/efeitos adversos , Estudos Prospectivos , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Astigmatismo/cirurgia , Estudos Longitudinais , Implante de Lente Intraocular , Córnea/cirurgia , Catarata/complicações
15.
Eye Contact Lens ; 49(10): 417-421, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37595277

RESUMO

OBJECTIVES: After penetrating keratoplasty (PK) for keratoconus, vision can be impaired by high-degree astigmatism, particularly in those patients with recurrent peripheral ectasia. Scleral contact lenses (CLs) have long been used in the management of keratoconus both in treatment-naive corneas and those postcorneal transplants. We report the use of miniscleral CLs and their related visual and clinical outcomes in a series of patients with post-PK peripheral rim ectasia. METHODS: In this retrospective case series, 5 patients (7 eyes) presented because of reduced visual acuity with their spectacles/CLs and/or reduced comfort with their existing rigid gas-permeable lenses. All patients in this series underwent PK more than two decades ago for keratoconus (mean 28.7 years±7.2). All patients demonstrated characteristic thinning at the graft-host junction, with anterior chamber deepening. Central corneas had remained clear in all patients inferring high visual potential. Contact lenses used were No 7 Comfort 15 miniscleral and the Onefit MED scleral with 14.5 mm and 15.6 mm diameters, respectively. RESULTS: All eyes achieved a best-corrected visual acuity of 6/9 or greater. One case had difficulty with insertion and removal and has since discontinued wearing lens at this time. All others are successfully wearing the lenses regularly. CONCLUSION: Despite advances in CL design, surgical management is still required in some patients. Miniscleral CLs are effective in the refractive management of peripheral ectasia in keratoconic post-PK eyes and should be considered in such eyes before proceeding with repeat surgical intervention.


Assuntos
Astigmatismo , Lentes de Contato , Transplante de Córnea , Ceratocone , Humanos , Ceratocone/cirurgia , Ceratocone/complicações , Astigmatismo/etiologia , Astigmatismo/cirurgia , Estudos Retrospectivos , Dilatação Patológica/etiologia , Dilatação Patológica/cirurgia , Acuidade Visual , Transplante de Córnea/efeitos adversos , Ceratoplastia Penetrante/efeitos adversos , Lentes de Contato/efeitos adversos
16.
J Cataract Refract Surg ; 49(11): 1140-1146, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37595291

RESUMO

PURPOSE: To assess effectiveness of individualized ray-trace based laser in situ keratomileusis (LASIK) for correction of myopia in everyday clinical practice. SETTING: Single-site private practice. DESIGN: Retrospective nonrandomised unmasked chart review. METHODS: Consecutive, myopic eyes (range ≤-8.25 diopters [D] sphere; astigmatism 0 to -4.25 D) treated with ray-trace based LASIK were included. Patients underwent wavefront, tomography, and biometry assessment using the InnovEyes Sightmap diagnostic device. The ray-trace based algorithm (InnovEyes algorithm) then generated an individualized 3D eye model and calculated a customized LASIK ablation profile. Postoperative visual acuity, refractive error and whole eye higher-order aberrations (HOAs) were evaluated over 3 months. RESULTS: The procedure was performed on 400 eyes (200 patients). Mean preoperative manifest refraction spherical equivalent was -3.39 ± 1.58 D (right eye -3.84 ± 1.63 D, left eye -3.98 ± 1.75 D). At month 3, uncorrected distance visual acuity (UDVA) was ≥20/20 in all eyes, ≥20/16 in 89% (right eye 90%, left eye 89%), ≥20/12 in 51% (54% right eye; 47% left eye), and 20/10 in 8% (right eye 8%; left eye 9%) of eyes respectively. UDVA was within 1 line of preoperative corrected distance visual acuity in 98% of eyes (right eye 98.5%; left eye 98%) and 39% of eyes (right eye 38%; left eye 39%) gained 1 line improvement. There was a statistically but not clinically significant increase in total HOAs (right eye 0.06 ± 0.133 µm; left eye 0.057 ± 0.125 µm; P < .001). The spherical aberration decreased (right eye -0.047 ± 0.095 µm, P < .001; left eye -0.051 ± 0.091 µm, P < .001). CONCLUSIONS: Ray-trace based LASIK was safe and effective for correction of myopia with and without astigmatism. Approximately, half the eyes achieved ≥20/12.5 UDVA and 8% achieved 20/10. There was no clinically significant increase in total whole eye HOAs.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Astigmatismo/cirurgia , Astigmatismo/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Aberrações de Frente de Onda da Córnea/diagnóstico , Lasers de Excimer/uso terapêutico , Refração Ocular , Miopia/cirurgia , Miopia/etiologia , Córnea/cirurgia
18.
J Cataract Refract Surg ; 49(10): 1025-1035, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37532255

RESUMO

PURPOSE: To determine (1) if measurements of surgically induced astigmatism (SIA) as measured by keratometry (K) and total keratometry (TK) differ (2) if SIA affects the magnitude and/or meridian of keratometric astigmatism (3) if SIA evolves over time. SETTING: Tertiary care center. DESIGN: Retrospective data analysis. METHODS: A swept-source optical coherence tomography biometry dataset (IOLMaster700) consisting of 498 eyes (327 patients) from a tertiary care center was analyzed. For all eyes preoperative and postoperative biometric measurements at 1-month, 3-month, and 6-months postoperative visits were considered for vector analysis of SIA K and SIA TK . RESULTS: Centroids in right and left eyes were 0.26 diopters (D) @5 degrees/0.31 D @1 degree for SIA K and 0.27 D @4 degrees/0.34 D @1 degree for SIA TK . Centroids for difference vectors K-TK in right and left eyes were 0.02 D @ 176 degrees/0.03 D @6 degrees. The mean SIA magnitudes in right and left eyes were 0.48 ± 0.41 D and 0.50 ± 0.37 D for SIA K and 0.53 ± 0.42 D and 0.54 ± 0.40 D for SIA TK . In eyes with ATR astigmatism, an increase in postoperative astigmatism magnitude was more common than a decrease. More than 30% of eyes showed changes in the meridian of more than 15 degrees. CONCLUSIONS: Overall, we observed differences in K- and TK-derived SIA, and changes in SIA magnitude over time. For postsurgical interventions, postoperative astigmatism meridian values should be measured to base treatments. Astigmatism magnitude showed a tendency to decrease for steep-meridian incisions and to increase in flat-meridian incisions.


Assuntos
Astigmatismo , Extração de Catarata , Catarata , Facoemulsificação , Humanos , Astigmatismo/diagnóstico , Astigmatismo/etiologia , Astigmatismo/cirurgia , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Córnea/cirurgia , Topografia da Córnea , Facoemulsificação/métodos
19.
Int Ophthalmol ; 43(11): 3989-3997, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37458945

RESUMO

PURPOSE: To evaluate the tolerance for refractive errors and visual outcomes of extended depth of focus intraocular lens (EDOF IOLs) in patients with previous corneal refractive surgery for myopia. METHODS: Patients from Aier Eye Hospital of Wuhan University with previous myopia excimer laser correction underwent cataract surgery and implantation of an EDOF IOL. The follow-up period was three months. The uncorrected distance, intermediate, and near visual acuities (UDVA, UIVA, UNVA), corrected distance visual acuity (CDVA), spherical equivalent (SE), defocus curve, optical quality, including modulation transfer functions (MTF) and Strehl ratio (SR), National Eye Institute Visual Functioning Questionnaire-14 for Chinese people (VF-14-CN), spectacle independence, and dysphotopsia were assessed. RESULTS: At the final visit, UDVA, CDVA, UIVA, and UNVA (LogMAR) were 0.06 ± 0.09, 0.01 ± 0.06, 0.11 ± 0.08, 0.20 ± 0.10, respectively. The mean spherical equivalent (SE) was - 0.57 ± 0.58D, sphere and cylinder were - 0.24 ± 0.60D, - 0.70 ± 0.58D respectively. No statistical difference in UDVA between eyes with SE in ± 0.50 D and in ± 1.0 D (p > 0.05). Corneal astigmatism > 1.00D has no significant effect on postoperative visual acuity (p > 0.05). The defocus curve showed that visual acuity could reach 0.2 in the refractive range of + 0.50D ~ - 1.50D. SR and MTF values were all higher than before the surgery. In bilateral implantation patients, the VF-14-CN questionnaire score and visual quality were quite excellent. CONCLUSION: The EDOF IOL have a certain tolerance for refractive errors and corneal astigmatism, and it's recommended for patients with prior myopia excimer laser surgery to achieve satisfactory visual performance.


Assuntos
Astigmatismo , Lentes Intraoculares , Miopia , Facoemulsificação , Erros de Refração , Humanos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Implante de Lente Intraocular/efeitos adversos , Facoemulsificação/efeitos adversos , Estudos Prospectivos , Lentes Intraoculares/efeitos adversos , Refração Ocular , Desenho de Prótese , Satisfação do Paciente
20.
Int Ophthalmol ; 43(11): 4333-4342, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37495937

RESUMO

BACKGROUND: Femtosecond laser-assisted in situ keratomileusis (FS-LASIK) with accelerated corneal crosslinking (FS-LASIK Xtra) is a recent procedure to achieve safer corneal ablation in myopic patients with borderline corneal thickness. Despite its well-accepted effectiveness, the development of remarkable interface haze is a potential concern but has rarely been reported and discussed. METHODS: We report for the first time a case series of 11 eyes of 7 patients who developed typical interface haze 1-3 months after FS-LASIK Xtra for the correction of myopia with astigmatism, with intensity grades ranging from 0.5 + to 3 + at the time of onset. RESULTS: The preclinical spherical diopters of the 7 patients ranged from - 2.25 D to - 9.25 D and cylindrical diopters ranged from - 0.25 D to - 2.50 D. The haze tended to be self-limiting, and topical anti-inflammatory therapy was given to moderate and severe cases, who responded well to treatment. CONCLUSIONS: The development of clinically significant interface haze is a relatively rare complication after FS-LASIK Xtra but tends to have a higher incidence and intensity compared to conventional stromal surgery such as FS-LASIK. Timely treatment and close follow-up are essential to patients undertaking FS-LASIK Xtra.


Assuntos
Astigmatismo , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Acuidade Visual , Lasers de Excimer/efeitos adversos , Córnea/cirurgia , Miopia/cirurgia , Astigmatismo/etiologia , Astigmatismo/cirurgia , Substância Própria/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...